• 论文
主办单位:煤炭科学研究总院有限公司、中国煤炭学会学术期刊工作委员会
风幕代替中心筒的旋风分离器性能研究
  • Title

    Performance of cyclone separator replacing vortex finder with air curtain

  • 作者

    孙世超周镇港袁东辉郑秀平段伦博

  • Author

    SUN Shichao,ZHOU Zhengang,YUAN Donghui,ZHENG Xiuping,DUAN Lunbo

  • 单位

    东南大学能源热转换及其过程测控教育部重点实验室内蒙古电力(集团)有限责任公司内蒙古电力科学研究院分公司内蒙古京泰发电有限责任公司

  • Organization
    Key Laboratory of Energy Thermal Conversion and Control,Ministry of Education,Southeast University;Inner Mongolia Electric Power Research Institute Branch,Inner Monglia Electric Power (Group) Co.,Ltd.,;Inner Mongolia Jingtai Power Generation Co., Ltd.,
  • 摘要

    旋风分离器是循环流化床锅炉中的重要设备之一,具有结构简单、造价便宜等优点,然而在循环流化床锅炉运行过程中容易发生旋风分离器中心筒变形、裂隙、下移甚至脱落等失效事故,造成了严重的经济损失。鉴于此,提出一种无中心筒旋风分离器,在原有中心筒位置引入无尘新风形成风幕用于调节旋风分离器的分离效率,避免中心筒失效事故且能灵活调整旋风分离器分离效率。采用冷态试验和数值模拟相结合的方法研究该无中心筒分离器的性能。研究发现:旋风分离器中心筒缺失后分离效率降低,在中心筒脱落后分别通入3、6、9、12 m/s风幕,分离效率先升高后降低,风幕速度为9 m/s时分离效率最高,较不通入风幕的分离效率提高3.17%;中心筒脱落后对于粒径小于6 μm的颗粒影响较小,与中心筒存在时的分级分离效率相差不大,而对粒径大于6 μm的颗粒影响较明显,远低于中心筒存在时的分级分离效率;形成风幕后能极大提高旋风分离器对粒径小于6 μm颗粒的分级分离效率。旋风分离器中心筒脱落后,压降略降低,在原有中心筒处通入无尘新风形成风幕后压降会升高,且压降随着风幕速度的提高而升高。

  • Abstract

    Cyclone separator is one of the important equipment in circulating fluidized bed boiler,which has the advantages of simple structure and low cost. However,many accidents such as deformation,crack,downward movement and even falling off of the vortex finder of the cyclone separator are easy to occur during the operation of the circulating fluidized bed boiler,resulting in serious economic losses.A cyclone separator without vortex finder was presented,and the dust free fresh air was introduced into the original vortex finder to form an air curtain to adjust the separation efficiency of cyclone separator,which could avoid the failure accident of vortex finder and flexibly adjust the separation efficiency of cyclone separator. The separation performance of the cyclone separator was studied by cold state experiment and numerical simulation. The results show that the separation efficiency of the cyclone separator decreases after the vortex finder falls off. Then the separation efficiency of the wind behind 3,6,9 and 12 m/s respectively increases first and then decreases. When the air curtain velocity is 9 m/s,the separation efficiency is the highest,which is 3.17% higher than that of the cyclone separator without air curtain. After the shedding of the vortex finder,the fractional separation efficiency of particles with particle size less than 6 μm shows little change compared with that in the presence of the vortex finder. However,the fractional separation efficiency of particles with particle size greater than 6 μm is significantly lower than that in the presence of the vortex finder. The separation efficiency of cyclone separator for particles with particle size less than 6 μm can be greatly improved behind the wind. After the vortex finder of cyclone separator falls off,the pressure drop will decrease slightly. When the fresh air is introduced into the original vortex finder,the pressure drop behind the wind will increase,and the pressure drop will increase with the increase of the wind curtain speed.

  • 关键词

    旋风分离器分离效率风幕循环流化床锅炉冷态试验CFD模拟

  • KeyWords

    cyclone separator;separation efficiency;air curtain;circulating fluidized bed boiler;cold model;CFD simulation

  • 基金项目(Foundation)
    国家重点研发计划资助项目(2019YFE0100100-08)
  • 文章目录

    0 引言

    1 试验

       1.1 研究对象

       1.2 研究方法

    2 结果与分析

       2.1 模型验证

       2.2 风幕对旋风分离器的影响

    3 结论

  • 引用格式
    孙世超,周镇港,袁东辉,等.风幕代替中心筒的旋风分离器性能研究[J].洁净煤技术,2022,28(4):183-190.
    SUN Shichao,ZHOU Zhengang,YUAN Donghui,et al.Performance of cyclone separator replacing vortex finder with air curtain[J].Clean Coal Technology,2022,28(4):183-190.
  • 相关文章
  • 图表
相关问题

主办单位:煤炭科学研究总院有限公司 中国煤炭学会学术期刊工作委员会

©版权所有2015 煤炭科学研究总院有限公司 地址:北京市朝阳区和平里青年沟东路煤炭大厦 邮编:100013
京ICP备05086979号-16  技术支持:云智互联