Title
Anthracite ignition characteristics in an arch-fired boiler with slot burners
-
作者
刘鹏远张海申浩树吴玉新张缦
-
Author
LIU Peng-yuan,ZHANG Hai,SHEN Hao-shu,WU Yu-xin,ZHANG Man
-
单位
清华大学热科学与动力工程教育部重点实验室
-
Organization
Key Laboratory for Thermal Science and Power Engineering of Ministry of Education,Tsinghua University,Beijing 100084,China
-
摘要
针对采用缝隙式燃烧器的600 MW超临界W火焰锅炉进行了热态试验研究,着重考察了不同工况下无烟煤煤粉气流的着火特性。试验结果表明,煤粉气流着火特性受燃烧器配风和煤粉浓度影响较为敏感。较低的一次风速可以显著缩短浓相煤粉气流着火距离,在1 m左右可以稳定的着火;二次风应在煤粉气流着火后补入,过大或过小的二次风均容易引起燃烧恶化;无烟煤煤粉气流的燃烧宜采用较高的煤粉浓度,煤粉浓度提高至1.0 kg/kg后浓相煤粉气流的着火更加稳定。控制合适的煤粉气流着火距离对W火焰锅炉运行非常重要,着火延迟距离过大后会引起火焰中心的下移从而容易造成冷灰斗区域的温度过高。
-
Abstract
Experimental studies were conducted on the anthracite ignition characteristics under different conditions in a 600 MW supercritical arch-fired boiler equipped with slot burners. The experimental measurements reveal that the igni- tion distance of the pulverized coal flows is affected by the air distribution of the burner and pulverized coal concentra- tion. The ignition distance of the fuel-rich flows become remarkably shorter under the low primary velocity. The fuel- rich flows could be ignited at about 1 meter away from the burner. The secondary air should be added into the primary flows after being ignited and it is ease for the excess or deficiency of secondary air to cause the deterioration of com- bustion. A higher concentration of pulverized coal is favorable for anthracite ignition. Ignition of the fuel-rich flows be- come more stable after rising the concentration of pulverized coal to 1. 0 kg / kg. Appropriate ignition distance of pulver- ized coal flows is very important to the operation of arch-fired boilers. The delayed ignition distance of pulverized coal could lower the flame center and cause the high temperature of the hopper region.
-
关键词
W火焰锅炉缝隙式燃烧器着火特性温度场
-
KeyWords
arch-fired boiler;slot burners;ignition characteristics;temperature field
-
基金项目(Foundation)
国家科技支撑计划资助项目(2015BAA04B01);
-
DOI
-
Citation
Liu Pengyuan,Zhang Hai,Shen Haoshu,et al. Anthracite ignition characteristics in an arch-fired boiler with slot burners[ J]. Journal of China Coal Society,2016,41(10):2466-2472.
-